DB-60

The DB-60 is the right equipment for the toughest dust control jobs. The fine mist created by our units captures airborne dust particles and drives them to the ground, helping you adhere to the toughest air quality standards. The DB-60 can cover up to 21,000 square feet (1,950 square meters) with up to 40° of oscillation, giving you a heavy-duty, long-range dust suppression. For those needing broader coverage, this unit can be outfitted with optional 359° oscillation, increasing its coverage area to nearly 125,000 square feet (11,813 square meters).

 

General Specifications

  • 25 HP fan.
  • 21,000 square feet (1,950 square meters) coverage. Nearly 125,000 square feet (11,613 square meters) coverage available with optional 359° oscillation.
  • Oscillator gives 0-40° of movement. Unit can also be equipped with optional 359° oscillation.
  • Adjustable angle of throw 0-50° of height adjustment.

Electrical Specifications

  • U.S.: 3 Phase / 25 HP fan / 480 Volt / 60 Hertz. Full load current is 46 amps. 60 Kw gen set is recommended.
  • Other motor options available, including all international electrical motors:
    • 3 Phase / 25 HP fan /380 Volt / 50 Hz (Europe, Middle East, N. Japan, Latin America)
    • 3 Phase / 25 HP fan /400 Volt / 50 Hz (Europe, Japan, New Zealand, Australia)
    • 3 Phase / 25 HP fan /415 Volt / 50 Hz (Europe, New Zealand, Australia)
    • 3 Phase / 25 HP fan /575 Volt / 60 Hz (Canada)
    • 3 Phase / 25 HP fan /380 Volt / 60 Hz Korea)
    • 3 Phase / 25 HP fan /440 Volt / 60 Hz (Mexico)
  • 10 HP (7.5 Kw) high pressure booster pump with no lift.
  • 1/8 HP (0.10 Kw) oscillator.
  • 150 foot (45.72 meters) 6/4 electrical cord. Other options available.
  • No male plug, "bare wired" is standard. Any plug is extra cost.
  • Cabinet with control panel.

Water Specifications

  • 10PSI (0.69 BAR) constant pressure needs to be delivered to booster pump. Maximum inlet water pressure should not exceed 100 PSI (6.89 BAR) when operating the booster pump.
  • Maximum PSI delivered by booster pump is 200 PSI (13.79 BAR).
  • Filter is included and should be used at all times. Contact us for recommendations when using nonpotable water. (Filter system in-line 30 mesh 595 micron).
  • 1-1/2" (38.10 mm) cam-and-groove quick disconnect female coupling for fire hose provided on machine.
  • 30 brass nozzles (also available in stainless and nylon).
  • Droplet size of 50-200 microns.
  • Throw 200 feet (60 m).

Noise Levels

Dimensions

on standard wheeled carriage

  • 6.75 feet (81 inches; or 2.06 meters) wide.
  • 9.75 feet (117 inches; or 2.97 meters) long.
  • 7.17 feet (86 inches; or 2.19 meters) tall.
  • 1800 lbs. (816.50 Kilograms).

Maintenance

  • If using potable water, nozzles need to be inspected once a year.
  • Fan motor and high pressure pump should be greased every 10,000 hours.
  • Oscillator bearing should be greased on a regular maintenance schedule, or as needed.

Chemical Additives

  • Can be used with surfactant to improve binding of dust particles or with tackifying agents to seal the ground to prevent dust from becoming airborne.
  • Odor control chemicals can be used to help eliminate odor.

Options

  • Unit is available with optional 359º oscillation. Standard oscillation provides 0-40º of movement.
  • Available on frame with skid mount. Unit comes standard on wheeled carriage.
  • Dosing Pump can be added to the unit for chemical applications.

Warranty

  • Unit is covered by 3-year / 3,000-hour warranty.